Poorly ventilated buildings are allowed under Australia rules – it's time to fix it

  • Written by Geoff Hanmer, Adjunct professor of architecture, University of Adelaide
Poorly ventilated buildings are allowed under Australia rules – it's time to fix it

If COVID-19 had taught us anything it surely must be that poorly ventilated buildings can be a health hazard. Yet due to a weakness in current rules they continue to be built.

Under Australia’s National Construction Code[1] it is possible to build a nightclub for 1,000 people with no ventilation. And it is possible to build a school for 600 people with no ventilation, or an aged care centre for 300 people with no ventilation.

This is because the Code requires windows that can be opened for natural ventilation, but nothing requires them to be opened in service.

And where the Code requires mechanical ventilation (fans or air conditioning) it is possible to build a hospital where the air that is supplied to patient rooms travels back to the air conditioning unit via corridors. A recent design in Footscray[2] is typical.

This means that visitors, patients and health care workers have to travel through airborne effluent from unwell people to reach them.

Rules for water, few for air

The Code has rules for ensuring the purity of water delivered through plumbing, but no rules for ensuring the purity of air, or requirement to deliver a minimum standard of ventilation in buildings accessed by the public.

The Code’s revised Indoor Air Quality Handbook[3] is now out for consultation[4].

The handbook is a guide for practice that is meant to go beyond the bare bones of the Code.

The revisions include nothing that would ensure indoor air was free from particulates, carcinogenic gases such as nitrogen oxide and benzine, pathogens such as bacteria, mould and fungal spores, or viruses – such as COVID-19.

Read more: Poorly ventilated schools are a super-spreader event waiting to happen. It may be as simple as opening windows[5]

The Code and Handbook say buildings can be “deemed to satisfy” air quality requirements if they provide one of two things:

  • “natural ventilation” using openable windows measuring 5% of the floor area

  • “mechanical ventilation” complying with Australian Standard 1668.2[6]

But no law or regulation prevents the construction of a naturally-ventilated building that can be operated with its windows shut.

In a home, opening and shutting windows is within the control of the occupant.

But in a publicly accessible building, occupants normally are unable to control windows, and in winter or summer they are often shut to control the temperature.

Airborne particles kill millions

Worldwide, pre-COVID, acute respiratory illnesses such as colds and influenza caused an estimated 18 billion upper airway infections and 340 million lower respiratory infections every year, resulting in more than 2.7 million deaths[7] and economic losses in the billions.

More broadly, tiny particles with widths as small as small as 2.5 microns[8] (PM 2.5) were responsible for more than four million[9] deaths each year.

Read more: I live in an apartment. How can I cut my risk of getting COVID?[10]

One single airborne viral disease, COVID-19, has now claimed between 17 million and 25 million[11] lives worldwide. Most transmission occurred indoors[12].

Good ventilation and high-efficiency particulate absorbing filtration could have prevented much of it.

This ought to be fixed at the top, with national indoor air quality standards that progressively apply to all buildings accessed by the public.

No parts-per-million standard

Ideally, the standards would include upper limits for all contaminants, down to and including a width of 2.5 microns.

These contaminants include bacteria, viruses, pollen and spores as well as particulates from bushfire smoke, vehicles and combustion processes.

Ventilation should also be sufficient to ensure that gaseous contaminants generated by building contents and indoor activities stay at safe levels.

Relatively inexpensive and reasonably accurate handheld devices[13] are now available to measure contaminants and could be used to monitor compliance.

Portable CO2 meters are not expensive.

Schools ought to be the first priority.

Many schools operated by state and Catholic education systems suffer from a massive shortfall in capital spending, contrasting with Rolls-Royce provisions at many high-fee private schools.

Nearly all state and low-fee schools operate in buildings in which heating, ventilation and air conditioning is an overlay on a natural ventilation.

Usually, these systems just recirculate air, or worse, in the case of unflued gas heaters, pollute it. Teachers ought not to be placed in the position of having to choose between thermal comfort and good ventilation.

This should not mean windows are set so they are always open. It should mean the building is safe even if the windows are shut.

This will cost money[14], but the benefits to children are likely to outweigh the costs.

The revision of the Indoor Air Quality Handbook is an opportunity for the Building Codes Board to start reforming the code so it takes health into proper account, rather than continuing to kick the can down the road.

References

  1. ^ National Construction Code (ncc.abcb.gov.au)
  2. ^ Footscray (www.vhba.vic.gov.au)
  3. ^ Indoor Air Quality Handbook (consultation.abcb.gov.au)
  4. ^ consultation (consultation.abcb.gov.au)
  5. ^ Poorly ventilated schools are a super-spreader event waiting to happen. It may be as simple as opening windows (theconversation.com)
  6. ^ Australian Standard 1668.2 (infostore.saiglobal.com)
  7. ^ 2.7 million deaths (pubmed.ncbi.nlm.nih.gov)
  8. ^ 2.5 microns (www.nrdc.org)
  9. ^ four million (www.ncbi.nlm.nih.gov)
  10. ^ I live in an apartment. How can I cut my risk of getting COVID? (theconversation.com)
  11. ^ 25 million (www.economist.com)
  12. ^ indoors (theconversation.com)
  13. ^ handheld devices (theconversation.com)
  14. ^ cost money (theconversation.com)

Authors: Geoff Hanmer, Adjunct professor of architecture, University of Adelaide

Read more https://theconversation.com/poorly-ventilated-buildings-are-allowed-under-australia-rules-its-time-to-fix-it-189229

The Bulletin Magazine

How to Choose the Right Bed for Your Cat

There are many different types of beds available for cats, and it can be difficult to decide which one is right for your pet - especially for thos...

NewsServices.com - avatar NewsServices.com

5 Tips For People Who Want To Make A Career Out Of Golfing

It might be difficult yet intriguing to figure out how to begin a career in golf. If you enjoy the sport, you've undoubtedly considered how thrill...

The Bulletin - avatar The Bulletin

Need a mood lift? We’ve tracked 4 ways Australia’s environment has repaired itself in 2020

When the clocked ticked over to 2020, Australia was in the grip of a brutal drought and unprecedented bushfires. But in the months since, while ...

Albert Van Dijk - avatar Albert Van Dijk